Our AdvantagesProducts Big quantity in Stock, No MOQ necessary We comply with all the intercontinental specifications, such as ISO9001 and TS16949 specifications. Our product variety also covers locking assemblies (clamping components/locking device), taper bushes, QD bushes, bolt-on hubs, torque limiters, shaft collars, motor bases and motor slides, chain detachers, chain guides, universal joint, rod finishes and yokes. If you need any details or samples, make sure you speak to us and you will have our quickly reply. We make all kinds of roots blower, centrifugal blower, Our Major goods are as underneath:

Sort Diameter Charge of stream Force
ESR-MJ(Intense Sort) Phi50~ Phi300mm .five~140m sup3/min nine.8KPa~ninety eight.8Kpa
ESR(Ordinary Variety) Phi50~ Phi350mm .5~140m sup3/min 9.8KPa~78.4Kpa
ESR-H(EPT-pressure Type) Phi50~ Phi350mm .7~160m sup3/min fifty eight.8KPa~98.8Kpa
ESR-V(Vacuum EPT) Phi50~ Phi350mm .five~160m sup3/min nine.8KPa~53.3Kpa
EL Sequence Phi200~ Phi600mm 20.three~750m sup3/min 9.8KPa~58.8Kpa
Multistage Centrifugal Blower
or C-Sequence
Phi250~ Phi500mm fifty~500m sup3/min 9.8KPa~98Kpa
ERR-ERG Sort Phi250~ Phi500mm one hundred twenty~420m sup3/min nine.8KPa~ninety eight.8Kpa

The functioning principle of the a few-blade roots blower: two three-lobed rotors are organized in the cavity, and the
suction port and the discharge port are opened on the two sides of the cavity. By way of the action of a pair of
synchronous EPTs, the two rotors rotate in reverse instructions and Relying on the mutual engagement of the two
rotors, the suction port and the discharge port are isolated, and the fuel in the chamber is pushed to attain the
purpose of blowing.

Feature of our roots blower:
1. Huge adjustment of the air volume
2. Minimal Sound
3. EPT efficiency
four. Reduced strength cosumption
5. EPTT time existence
6. Reliable working, easy routine maintenance,tiny footprint

The parameters of our roots blower:

Kind Ratary Speed
(r/min)
Pressure Rise
(Kpa)
Capacity
(m/min)
Shaft EPTT
(Kw)
EPT Device MaXiHu (West EPT) Dis.mn
Excess weight(Kg)
EPTT
(Kw)
ESR-50 1100-2120 9.8-fifty eight.8 .65-two.58 .three-3.54 .seventy five-four 128-158
ESR-65 1100-2130 nine.8-58.8 .94-3.66 .38-four.46 .seventy five-five.5 155-185
ESR-eighty 1140-1900 9.eight-58.8 2.34-5.43 one.04-seven.forty two 2.two-eleven 155-277
ESR-a hundred 1060-1980 nine.8-58.8 4.fifty seven-nine.05 1.35-twelve.fifteen 3-15 309-377
ESR-a hundred twenty five 980-1850 9.8-fifty eight.8 5.35-12.four one.sixty five-five.19 five.five-18.five 408-451
ESR-125C 970-1830 nine.8-fifty eight.8 seven.five-17.57 three.two-eighteen.5 4-22 408-451
ESR-one hundred fifty 810-1730 9.eight-fifty eight.eight ten.37-27.15 three.eighty four-forty.eighty two seven.five-forty five 688-848
ESR-a hundred seventy five 970-1520 9.8-58.eight 19.65-36.sixty five seven.2-forty five.ninety five eleven-fifty five 980-1080
ESR-200B 740-1450 nine.8-58.8 19.65-forty four.8 10.15-sixty.forty four fifteen-seventy five 1272-1546
ESR-two hundred 810-1480 9.8-58.8 27.sixty five-59.2 eight.05-eighty,twelve 15-90 1272-1546
ESR-250B 1100-1480 nine.eight-58.eight 54.seventy seven-seventy seven.fifty five 19.ninety seven-ninety.97 thirty-one hundred ten 1490-2454
ESR-250 990-1480 9.8-58.eight sixty one.four-97.52 twenty.one-117.three thirty-132 1490-2454
ESR-three hundred 990-1480 nine.8-fifty eight.eight 87.one-138.one 26.four-167.eight 37-185 3326-3446
ESR-350 730-1480 nine.eight-58.8 seventy eight.41-177.31 fifty five-250
ESR-50H 1230-2120 63.7-98 .forty five-two.02 2.05-six.twelve 3-7.five 160–one hundred seventy
ESR-65H 1240-2130 sixty three.7-98 .78-two.53 2.89-seven.55 4-eleven 198-230
ESR-80H 1140-1900 sixty three.7-98 1.82-four.fifty five four.09-ten.one five.five-fifteen 316-326
ESR-100H 1060-1980 sixty three.7-ninety eight two.65-eight.06 6.36-seventeen.2 seven.five-22 398-459
ESR-125H 980-1850 63.7-ninety eight four.64-eleven.23 8.ninety two-24.2 eleven-thirty 544-630
ESR-150H 810-1730 63.seven-ninety eight 9.53-25.seventy six seventeen.16-sixty five 18.5-75 752-1571
ESR-200H 810-1480 63.seven-ninety eight 25.34-56.92 42.34-one hundred twenty fifty five-132 1426-1934
ESR-250H 990-1480 63.7-ninety eight fifty eight-ninety three.seven eighty three.two-205 90-220 2980-3468
ESR300H 990-1480 sixty three.7-98 86.9-134.1 114.seven-270 132-280 3476-3998
ERF-245 650-980 nine.eight-98 forty seven.5-97.four 16-183 eighteen.five-two hundred 3630-3690
ERF-250 650-980 nine.8-98 61.6-120.4 19-227 22-250 4450-4500
ERF-290 650-980 9.8-seventy eight.4 92.three-128 22-213 30-250 4890-4710
ERF-295 650-980 nine.8-seventy eight.four ninety seven.3-152.five 23-227 30-250 4890-4880
ERF-297 650-980 nine.eight-seventy eight.4 87.five-167.6 26-249 30-280 5330-5520
ERF-300 650-980 9.eight-seventy eight.4 one zero one.five-188.7 29-278 37-315 5330-5520
ERF-350 650-980 nine.8-78.four 126-224.9 34-249 45-280 5210-6470
ERG-300 590-730 nine.8-98 128.3-196 38-362 45-four hundred 9440-15710
ERG-350 590-730 9.8-ninety eight 159.3-231.six 43-420 55-450 9700-1571
ERG-four hundred 590-730 9.eight-83.3 203.one-290.9 52-449 75-500 10090-11390
ERG-445 590-730 nine.eight-seventy three.five 229.7-327.eight 58-477 seventy five-560 10600-12230
ERG-450 590-730 nine.8-73.5 262.4-366.2 64-496 75-560 10600-12230
ERG-500 590-730 9.8-63.seven 327.four-452.4 seventy eight-529 ninety-560 12790-14620
ERF-240-V 650-980 -9.eight- -49 38.1-78 13-seventy six eighteen.5-90 3420-3285
ERF-245-V 650-980 -9.8- -49 forty seven.5-97.4 16-95 22-110 3425-3360
ERF-250-V 650-980 -nine.8- -forty nine sixty three-a hundred and twenty 19-117 22-132 3910-3830
ERF-290-V 650-980 -9.8- -forty nine seventy two.6-a hundred and forty four 22-136 thirty-one hundred sixty 4415-4270
ERF-295-V 650-980 -nine.eight- -forty nine seventy six.6-152 23-145 30-one hundred sixty 4425-4485
ERF-297-V 650-980 -nine.8- -49 84.3-166.8 26-one hundred sixty thirty-one hundred eighty 5000-4980
ERF-three hundred-V 650-980 -nine.eight- -forty nine ninety seven-192 29-178 37-200 5000-4980
ERF-350-V 650-980 -9.eight- -forty nine 116-225 34-209 forty five-250 5400-5700
ERG-300V 590-730 -nine.eight- -49 133-193 38-184 45-220 7800-9100
ERG-350V 590-730 -nine.eight- -49 163-231 43-216 55-250 9500-9470
ERG-400V 590-730 -9.eight- -49 199-290 52-269 75-315 9900-10130
ERG-445V 590-730 -nine.eight- -49 224.eight-326.nine fifty eight-303 seventy five-355 9900-10130
ERG-450V 590-730 -nine.8- -49 255-365 64-335 75-four hundred 11230-11300
ERG-500V 590-730 -nine.eight- -49 314-452 78-412 132-450 13630-13850
ERF-245W 650-980 -13.3- -53.3 fifty three.five-one hundred and one 21.five-102 30-a hundred and ten 3630-3360
ERF-250W 650-980 -13.3- -53.three 69-127 26.five-127 thirty-160 3985-4115
ERF-290W 650-980 -thirteen.3- -fifty three.3 82.six-one hundred fifty 30.five-149 37-185 4340-4580
ERF-295W 650-980 -thirteen.three- -fifty three.three 87-158 32-158 37-185 4440-4580
ERF-297W 650-980 -13.3- -fifty three.three 95-174 36-174 forty five-200 5230-5130
ERF-300W 650-980 -13.three- -fifty three.three 109-195 40-193 fifty five-220 5230-5130
ERF-350W 650-980 -13.3- -fifty three.three 129-230 50-230 75-250 5840-5670
ERG-300W 590-730 -13.three- -fifty three.three 142-197 52-201 75-220 9100-9000
ERF-350W 590-730 -thirteen.3- -53.3 168-234.four 59-235.five 75-280 9500-9600
ERG-400W 590-730 -thirteen.3- -fifty three.three 220-276.6 71-292 ninety-315 9900-10130
ERG-445W 590-730 -thirteen.3- -fifty three.3 244-294.6 82-331 ninety-four hundred 11230-11300
ERG450W 590-730 -thirteen.three- -fifty three.3 275-368.five ninety one-366 110-400 11230-11300
ETRF-250
(240,250)
650-980 98-196 sixty four.eight-112 one hundred thirty five-355 one hundred sixty-four hundred 8700-8600
ETRF-295
(245,295)
650-980 98-196 eighty.8-139 167-439 185-five hundred 9200-9100
ETRF-300
(245,295)
650-980 ninety eight-176.4 102-174 206-497 250-560 10320-10500
ETRF-350
(245,295)
650-980 98-137.2 124-207 241-473 280-560 10700-11110
ETRG-four hundred
(three hundred,four hundred)
590-740 ninety eight-176.4 205-273 380-773 450-900 21350-24200
ETRG-450
(350,450)
590-740 ninety eight-176.4 263-428 476-955 560-one thousand 24200-27600
ETRF-250W
(240,250)
650-980 -53.three–80 seventy two-121 seventy five.6-121 ninety-a hundred and sixty 6100-6470
ETRF-295W
(245/295)
650-980 -fifty three.three–eighty 93.8-154 99.five-186 a hundred and ten-220 7000-6400
ETRF-300W
(2505/300)
650-980 -fifty three.3–80 116-189 a hundred and fifteen-220 132-250 7750-7760
EL81WD 580-980 9.eight-58.eight 54.two-130 eighteen-151 forty five-185 3595
EL82WDB 580-980 9.8-fifty eight.8 72.eight-161 22-191 forty five-220 3860
EL83WDA 580-980 9.eight-fifty eight.9 a hundred and one-213 28.5-202 45-220 4300
EL84WDA 580-980 9.eight-58.8 129-267 35.four-252 forty five-280 4720
EL93WDA 580-730 nine.eight-49 230-329 56.four-311 75-355 7765
EL94WDA 580-730 9.8-49 263-373 sixty four-353 seventy five-400 8130
EL95WDA 490-580 9.eight-58.eight 308-434 eighty one.4-414 ninety-450 11500
EL96WDA 580 fifty eight.eight 381 497 560 11500
E397WN one thousand-1650 40 5-9
E408WN 870-1650 forty 10-22
E517WN 980-1580 40 20-thirty
E520WN 930-1550 40 24-45
E607WN 750-1250 forty 45-seventy six
E610WN 750-1250 40 seventy five-a hundred thirty

EPT elements and composition of our roots blower:

Package deal of our Roots Blower

Pack into iron case, two layer,blower entire body and motor in decrease layer, inlet/out silencer and so forth in upper layer

Roots blower pack approach same as iron situation, just alter to Fumigation Free of charge Plywood Situation

Our factory is a skilled producer of Roots blowers which has over twenty years’ experience in EPTTry
manufacturing. It is found in XiHu (West EPT) Dis.hu (West EPT) Dis. EPT EPTT Park, 50 kilometers to the EPT of ZheJCEP provincial
funds— EPTEPTTn. Our organization also has handy site visitors transportation, as it is 15 kilometers absent from
Diaozhen City station of EPTTngdao-HangEPT expressway, and thirty kilometers away from EPT EPTEPTTn station of
BeiEPTTg-ZheJCEP expressway.The top solution of our company is ESR -sort Roots Blower. The roots
EPT pump is a new variety of substantial-effectiveness roots blower, which is deveXiHu (West EPT) Dis.Hu (West EPT) Dis.ed independently primarily based on the
domestic and foreign EPTd systems. Many patEPTTd technologies have been adopted on Roots
Blower, and therefore we have created significant outcomes in power conservation and sounds reduction, etc.. So far, our
firm has invested far more than thirty,000,000 RMB to introduce such EPTd expert products as
horizontal machining cEPTTr, vertical machining cEPTTr, two-way CNC surface area planer, CNC lathe, CNC milling
EPTT, CNC planer, aircraft grinder, cylindrical grinding EPTT, and 3 coordinates tests EPTT.
Besides, we have taken a variety of actions to stXiHu (West EPT) Dis.Hu (West EPT) Dis.rdize the approach flow this sort of as functioning and cooperating
with a lot of EPT research units, schools and universities at residence and overseas. We also continuously try out to
take up and increase the domestic EPTd production technologies, so as to promote the upgrading and
optimization of the product and make the merchandise top quality achieve the EPTd level at home and abroad.
ESR -type Roots Blower incEPTTs a number of series these kinds of as 3-leaves Type, Two-leaves Sort and Centrifugal
Sort,which can be even more divided to hundreds of types. The products are extensively utilised in sewage remedy,
pneumatic conveying,EPT EPTT, aquaculture, foods processing, electrical EPTT, petrochemical, cement,
mining and other EPTT. Our merchandise have this kind of benefits as minimal sounds, energy saving, secure quality,
and EPTT provider lifestyle, and so on.. With the product sales outlets throughout the domestic capital metropolitan areas, our products sell well all
more than the place, and have been exported to North America,Russia, Malaysia, Indonesia, Vietnam, South Africa
and some other international locations. Having obtained the ISO9001 JCEP EPTT Method Certification, we have
estabEPTTd and improved the top quality assurance of the merchandise developing, producing, and installation.
From the procedure of layout, research and deveXiHu (West EPT) Dis.Hu (West EPT) Dis.ment to the finished goods, we have got the EPTT
process controlled independently, therefore providing the complete basis and reliability guarantee for the merchandise balance
and longevity. Obtaining a excellent income community and following-income support, we offer our customers with larger-
top quality and more effective support.All workers of our organization sincerely welcome the wide masses of close friends to
XiHu (West EPT) Dis.Hu (West EPT) Dis., and negotiate business with us.

Our Roots Blower Workshop

Doosn Horzitonal EPTT CEPTTr

The Software of the Roots Blower

Servicing and inspection
(1) Verify all fasteners and locating pins problems no matter whether they are loosening.
(2) AlwaEPTTcheck whether or not the leakage phenomenon of the body.
(three) Shell out focus to lubrication, amount of grease and noises when running,
deterEPT whether or not it performs unEPTTthe JCEP conditions.
(four) Lubricant amp grease: The lubricant is for medium load EPTT EPT oil
(quality 220, kinematic viscosity of 198 ~ 242mm2 / s forty ordmC, flash position ge 200 ordmC)
The grease is butter (artificial lithium grease penetration 220-250, drop stage ge
one hundred ninety ordmC). Change the lubricant and grease right after 1st two hundred hours managing, and change
once again after a moth operating. Later on, exchange the lubricant and grease according to the
environment and lubricant (grease) quality suggest a suitable replacement for three
months.
(five) AlwaEPTTcheck the inlet air filter, clear or substitute the filter in time.
(six) Blower overload at times not quickly shown, so pay consideration to
the ingestion and exhaust pressure, bearing temperature and the recent boost developments
of motor to deterEPT whether or not the blower operates normally
(7) Ahead of disassembling the blower, the assembling relation and dimensions
need to be recorded or calculated, make marks on elements to make certain the original
demands right after assembling.
(eight) When freshly EPTT or overhaul, the oil tank ought to be cleaned ahead of use
and suggest substitute all grease following 8 hrs operating.

Frequent failure purpose and troubleshooting

No Failure Possible motives Elimination methods
1 Friction
in between the
impeller
(1) EPTTurities on the impeller,
ensuing in the hole is as well small
(two) EPT dress in, ensuing in a
large backlash
(three) The EPT is not well fixed,
can not preserve the impeller
synchronization
(4) EPTT use ensuing in
clearance rising.
(one) Eliminate dirt and check out
whether there is harm areas
(2) Adjust the EPT gap, replace
the EPTs if the EPT backlash is
higher than the average 30% to
50%
(3)Re-assemble the EPTs, keep
the EPTTr get in touch with region is to seventy five%
(four)Substitute the bearing
two Collision
among
impeller and
wall, the
impeller best
and casing
(one) Installation hole is not appropriate
(two) operating force is way too
large, exceeding the specified
worth
(three) Functioning temperature is also high
(4) Casing or base deformation,
positioning supporter failure
(five) EPTT aXiHu (West EPT) Dis.al area is not very good
(1) Modify the hole
(2) Discover leads to of
overloading, lowered the force
to the specified price
(3) Check the set up
accuracy and minimize the pipe
tension
(four) Check out and repair bearings,
and to make certain the clearance
(5)Relocation
three Temperature
too higher
(1) Oil in tank is also significantly, also
thick or way too dirty
(two) EPT or silencer is blocked
(3)The pressure is higher than
the specified price
(four)Extreme dress in of the
impeller, massive gap
(5)Inadequate air flow, indoor
temperature is high, resulting in
inlet air’s substantial temperature
(6) The rotating pace is too lower,end result in the belt slipping.
(1)Decrease the oil amount or rely on
oil
(two)Get rid of of blocking objects
(3)Reducing the stress by means of
the blower
(4)Fix its clearance
(five)Open vents to lessen space
temperature
(six) Boost velocity to stop the
belt slipping.
4 Insufficient
movement
(1) The inlet filter is blocked
(two) EPTTeller put on and the hole
boosts way too significantly
(three) Belt slipping
(four) Huge EPTTs stress reduction
(5) EPTline ventilation leakage
(one) Thoroughly clean the filter dust and
obstruction
(2) Repair the hole
(three)Tighten the belt and improve
the variety of belts
(4)Adjust the inlet strain to the
specified price
(5) Examine and restore the pipeline
five Oil leaking or
oil leaking
into the enclosure
(one)EPT tank placement result in
leakage from the discharge port
(2) Seal dress in, resulting in shaft oil spills
(3) The pressure is greater than
the specified benefit
(1)Minimize the oil degree
(two)Substitute the seals
(three)Clear the air vents, 2mm diameter faucet is mounted in the
middle chamber, open the faucet
unEPTTthe wall
six Irregular
vibration and
sounds
(one)EPTT clearance exceeds the
specified worth or bearing use
(two) The EPT backlash is too
big, not in a tigEPTT mounted
(3) The overseas objects and dust
caused by the impeller and the
impeller, the impeller and the
housing collision
(4) the impeller shaft
deformation induced the collision
caused by overload,
(five) Friction among the impeller
and the inlet housing triggered by
overheating
(6) Unbalance of the impeller
caused by fJCEP or overseas
human body
(seven) Anchor bolts or other
fasteners are loosened
(one)Substitute bearings or bearing
seat
(2)Reassemble EPT and guarantee
backlash
(three)Cleaning blower, check the
circumstance is destroyed
(four)Check the back strain, examine
the wheel and adjust hole
(5)Verify the filter and again
force, enhance the gap
amongst the impeller inlet and the
casing
(6)Cleanse the impeller and the
casing, to make certain that the impeller
clearance function
(7) Tighten the anchor bolts and
leveling the base.
seven EPT
overload
(one)Compared with the JCEP
strain, the pressure difference
is massive that the back force or
the inlet strain is high
(two) When compared with the
gear demands, blower
stream is too massive, so its strain
increases
(3)Inlet filter is blocked, or outlet
pipe is obstructed or blocked
(four) Collusion or friction (caught)
rotating elements
(five) The oil stage is also high
(6) NEPT V-belt is overheat,
vibration is too big, or pulley
is also tiny
(one) Lessen the pressure to the
specified price
(two) Exhaust the excessive gasoline into
the environment or minimize the
blower pace
(3) Remove the obstructions
(4)Right away shut down, check
the cause
(five) Change the oil to the right
degree
(six) Check the belt tension, and
changed it with large diameter
pulley.

Our Services

1. Pre offer service two. Right after market services
a. advise the appropriate design c. online complex support,
b. manufacturing unit tour d. EPTT life spare parts and techinical assistance

Gurantee

twelve months gurantee for our roots blowers

  in Mandalay Myanmar  sales   price   shop   near me   near me shop   factory   supplier Φ 150mm Double Oil Case Roots Blower with 37kw Motor manufacturer   best   Cost   Custom   Cheap   wholesaler

Tags:

rubber coupling

As one of leading rubber coupling manufacturers, suppliers and exporters of products, We offer rubber coupling and many other products.

Please contact us for details.

Mail:sales@rubber-coupling.com

Manufacturer supplier exporter of rubber coupling

Recent Posts